KONTAKTOR 12A 3P+1SL 24V DC LP1K1201BD
Product number
4178372
TeSys K contactor, 3p(3 NO), AC-3, <= 440 V 12A, 24 V DC coil
TeSys K contactor, 3p(3 NO), AC-3, <= 440 V 12A, 24 V DC coil. range: TeSys - product name: TeSys K - product or component type: contactor - device short name: LP1K - contactor application: motor control, resistive load - utilisation category: AC-1, AC-3, AC-4 - poles description: 3P - pole contact composition: 3 NO - [Ue] rated operational voltage: <= 690 V AC 50/60 Hz for signalling circuit, 690 V AC 50/60 Hz for power circuit - [Ie] rated operational current: 12 A at <= 440 V AC AC-3 for power circuit, 16 A (<= 70 °C) at 690 V AC AC-1 for power circuit, 20 A (<= 50 °C) at <= 440 V AC AC-1 for power circuit - motor power kW: 3 kW at 220...230 V AC 50/60 Hz, 4 kW at 480 V AC 50/60 Hz, 4 kW at 500...600 V AC 50/60 Hz, 4 kW at 660...690 V AC 50/60 Hz, 5.5 kW at 380...415 V AC 50/60 Hz, 5.5 kW at 440 V AC 50/60 Hz - auxiliary contact composition: 1 NC - overvoltage category: III - [Ith] conventional free air thermal current: 10 A at <= 50 °C for signalling circuit, 20 A at <= 50 °C for power circuit - Irms rated making capacity: 110 A AC for signalling circuit conforming to IEC 60947, 144 A AC for power circuit conforming to IEC 60947, 144 A AC for power circuit conforming to NF C 63-110 - rated breaking capacity: 110 A at 440 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947 - [Icw] rated short-time withstand current: 100 A <= 50 °C 10 s power circuit, 105 A <= 50 °C 5 s power circuit, 110 A 100 ms signalling circuit, 115 A <= 50 °C 1 s power circuit, 25 A <= 50 °C <= 15 s power circuit, 50 A <= 50 °C 3 min power circuit, 55 A <= 50 °C 1 min power circuit, 75 A <= 50 °C 30 s power circuit, 80 A 1 s signalling circuit, 90 A 500 ms signalling circuit - associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660, 25 A aM for power circuit, 25 A gG at <= 440 V for power circuit - [Ui] rated insulation voltage: 600 V for power circuit conforming to CSA C22.2 No 14, 600 V for power circuit conforming to UL 508, 600 V for signalling circuit conforming to CSA C22.2 No 14, 600 V for signalling circuit conforming to UL 508, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-5-1 - electrical durability: 0.3 Mcycles 20 A AC-1 at Ue <= 440 V, 1.3 Mcycles 12 A AC-3 at Ue <= 440 V - mounting support: plate, rail - standards: BS 5424, IEC 60947, NF C 63-110, VDE 0660 - product certifications: CSA, UL - connections - terminals: screw clamp terminals 1 cable(s) 0.34...2.5 mm² - cable stiffness: flexible - with cable end, screw clamp terminals 1 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end, screw clamp terminals 1 cable(s) 1.5...4 mm² - cable stiffness: solid, screw clamp terminals 2 cable(s) 0.34...1.5 mm² - cable stiffness: flexible - with cable end, screw clamp terminals 2 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end, screw clamp terminals 2 cable(s) 1.5...4 mm² - cable stiffness: solid - tightening torque: 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 - operating time: 10 ms coil de-energisation and NO opening, 30...40 ms coil energisation and NO closing - safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - mechanical durability: 10 Mcycles. Benefits: Tesys k forms a complete range of reversing or non-reversing contactors, offering the best performance/compactness ratio and seamless integration in all your applications.... Applications: Industry, infrastructure, building, etc:, Simple control systems, Zones sensitive to noise, disturbed mains supplies: silent contactor, Use compatible with programmable controller outputs: low-consumption contactor, Switching contactor or relay coils, Powering control and signalling equipment..
Product details
Technical specifications
Rated control supply voltage AC 50 Hz0 ... 0 V
Rated control supply voltage AC 60 Hz0 ... 0 V
Rated control supply voltage DC24 ... 24 V
Voltage type for actuatingDC
Number of normally closed contacts as main contact0
Number of normally open contacts as main contact3
Type of electrical connection of main circuitScrew connection
Rated operation current Ie at AC-1, 400 V20 A
Rated operation current Ie at AC-3, 400 V12 A
Rated operation power at AC-3, 400 V5.5 kW
Rated operation current Ie at AC-4, 400 V6 A
Rated operation power at AC-4, 400 V2.2 kW
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact1
Modular versionfalse
Product codes
SAPGBJ876
PLC4178372
STK4178372
GTIN/EAN3389110790771
Manufacturer part numberLP1K1201BD
Vendor material numberLP1K1201BD
Basic information
Package measurements (L x W x H)48 x 62 x 66 mm
Package volume0.196 l
Package weight0.22 kg
Base uniteach
Package units1
Usage quantity1
UNSPSC39121529
BrandSCHNEIDER